A, the crankshaft and bearing oil should be clean and smooth, crankshaft oil plug plug and counterweight locking device should be tightened; Second, bearing steel shell and skf Bearings http://htjal.ymyu3.com/ alloy layer of adhesive should be strong, and without hulling and retuned phenomenon;
Three, bearing and the Bearing skf http://dewff.ymyu3.com/ seat on the back should fit closely, the contact area should not be less than 70%;
Four, bearings with radial and axial clearance between main journal should comply with the provisions of the equipment technical documents;
Five, the tile under the open of thick wall bearings and shaft neck of the contact surface should not be less than 90 ° Angle, contact area should not be less than 70% of the contact surface area;Of four open bearings and shaft neck and side watts under contact area should not be less than 70% of each tile area;
Six, thin wall tile, tile and tile back seat should fit closely;When bearing outside diameter less than or equal to 200 mm, its contact area should not be less than 85% of tile back area, when bearing outside diameter greater than 200 mm, the contact area should not be less than 70% of tile back area, and the contact should be uniform;Thin wall tile assembly clearance shall comply with the provisions of the equipment technical documents;The tile surface alloy layer should not be scraping the inquiry.When need to scrape research should scrape the inner surface of the bearing seat;
Seven, the level of the crankshaft installation deviation should not be more than 0.10/1000. And should be in the position of each crankshaft turn 90 °, with level measurement on the main journal;
Eight, the crankshaft axis perpendicularity of slide axis deviation should not be more than 0.10/1000
The above content are according to the problems encountered in the actual work arrangement, for your reference, if there is any question, please timely communication, correct.