Amine sweetening is a common unit process for the removal of sour gases in petroleum refining and natural gas processing. However, it can be a costly procedure that is often inefficient. Real-time, in-line pH analysis ensures sweetening is effective and money is not being wasted.Introduction
Fuel gases and off-gases in refinery operations as well as all natural gas contain a certain amount of acidic gases in the form of hydrogen sulphide (H2S) and carbon dioxide (CO2). Due to the corrosive and toxic properties of H2S, and the reduced caloric value caused by CO2, the levels of these gasses must be curtailed if the products are to be used or processed further. The removal of H2S and CO2 is usually achieved by passing the sour gas through an amine solution in an absorber unit. "Sweet" gas is extracted from the top of the absorber, and amine solution collected at the bottom and now rich in H2S and CO2, is passed to a regenerator unit where heat is used to strip the sour gasses from the amine. "Lean" amine is then fed back to the absorber.
Controlling amine sweetening
The removal of H2S and CO2 from sour gases by amine sweetening relies on maintaining the quality of the amine solution fed to the absorber and proper adjustment of heat at the amine regenerator. Insufficient heat results in incomplete amine regeneration, while excessive heat represents a costly waste of energy. Feeding the absorber with an amine solution that is not sufficiently lean means gas absorbance will not be optimal, and adding fresh amine when it is not required is simply throwing money away.
Value of pH monitoring
Simply by monitoring the pH upstream and downstream of the amine regenerator, the acid gas load of the amine solution can be easily measured. When the acid gas load is known, the heat at the regenerator can be adjusted to the point where it efficiently removes the acid gases from the amine solution. Degeneration of the amine solution is also simply detected, so fresh make-up amine can be added in order to ensure sufficient absorption.
Rugged electrodes
For the pH measurement itself, METTLER TOLEDO's InPro 4260i electrode is ideal as it is designed for extended life in harsh chemical environments. The InPro 4260i benefits from a solid electrolyte and an open junction instead of a diaphragm so that fouling of the sensor is minimized. Fitting a retractable housing, such as the InTrac 777e, allows any maintenance work to be conducted without interruption to the process.
Conclusion
Removal of H2S and CO2 from refinery and natural gases is a vital process in sour gas management. Achieving this through amine sweetening is effective and cost-efficient, providing that the amine solution used is sufficiently lean and that excessive use of heat at the regenerator is avoided. An in-line pH measurement solution from METTLER TOLEDO will not only verify that the amine sweetening process is doing its job, it is one of the simplest means of analyzing acid gas load, and ensuring that energy at the regenerator is not being wasted or that fresh amine is being misapplied.
For more information, please visit http://us.mt.com/us/en/home/supportive_content/specific_overviews/LandingPage_Process_ISM_Systems_1.html?crel=ePR_PP_EN
Contact information:
Mettler-Toledo International Inc.
Im Langacher, Zip Code 8606
Greifensee, Switzerland
E-Mail : ePublicRelations@mt.com
Phone : +41-44-944 33 85
Website : www.mt.com