As we all know, the electrode lifting automatic regulator to change the electrode position (arc length LARC), also followed the same time flexible cables in the space vertically (z direction) on the ever-changing, especially in the early melting, the flexible cables with high damping characteristics and unique to variability, so that it can cause changes in the electrical system status, such as it can seriously interfere with the arc current operating frequency, that is: it increased the arc current in the low-frequency components, the low-frequency components of the frequency range of 2 ~ 6Hz, resulting in electrical system reactance increases.In addition, the company's high-power arc of physical phenomena analysis and the results showed that: in the arc discharge process, the arc current is constantly fluctuating, the wave frequency range fi> 0.5 ~ 6Hz, caused by its role to the lifting system on the electric power compared with the frequency f = 2fi. Many uncertain factors affect the arc discharge path, resulting in the arc to 0.07 ~ 0.09Hz frequency of material from one block to another block of material transfer (arcing).
Studies have shown that: electric arc furnace in operation, resistance and reactance per phase value depends not only on the arc current and arc voltage of fundamental component and the harmonics, but also on the white power transfer characteristics. In the early melting electric arc furnace operating conditions, each phase of the electrical resistance and inductance values ??are very different from the same design, which in addition to the above reasons but also because three electrodes can not be in the same plane, resulting in phase between the phase and mutual inductance different.