Hollow bar system were used in the permanent application


Hollow bar system were used in the permanent application

BriefingWire.com, 5/14/2016 - Hollow bar system were used in this permanent application as an alternative to stand anchors. The speed of installation was on deciding factor. Also, in a seismically active region, strand anchors are monitored for relaxation and the anchor head must remain accessible. Restressing is often necessary in these conditions. T73/53 and T103/78 hollow bar tiebacks with an approximate maximum load of 1,500KN and an inclination of 10 degrees were used. The anchors were spaced between 1 and 2m. The bars were protected from corrosion using a corrugated sheath, and the heads were painted with corrosion inhibiting compound.

 
 