esolve common problems with your non-functioning heating system.Thermostat Check
Is the system selector switch in the “HEAT” position?
Is the temperature set at least 3 degrees above current room temperature?
If your thermostat is electronic, are the batteries charged? Is the display showing?
For Forced Air Furnaces Only: If your thermostat has a switch to control the furnace fan, switch the fan “ON”. (This switch will usually be located at the bottom of the thermostat, closer to the left side and will be marked “ON” and “AUTO”.) Listen to hear the furnace fan coming on. If you cannot hear the fan, go to one of the supply registers and see if you can feel any air coming out. If the fan is not running, there may be no power to the furnace.
If the thermostat is set properly, the next step is to check to see that there is power to the furnace.
Electrical Check – Furnace
Some heating systems also have emergency cut-out switches that are activated when a door or service panel is removed. Often the furnace door is not replaced properly after a filter cleaning and the cut-out switch will prevent the furnace from coming on. Check to make sure all access doors are properly secured and fitted.
Your heating system may be equipped with an emergency shut-off switch for the furnace. If your system is so equipped, locate it and make sure it is turned ON. In most homes, the emergency shut-off switch looks just like a regular light switch and will be located on the side or close to the furnace. Sometimes there is a second Red Emergency Toggle Switch that is typically located at the top of the basement stairs. It is quite common for this switch to be turned OFF accidentally. If is turned OFF make sure to turn it back into the ON position. if the switch is ON, but the fan still doesn’t operate, proceed to the Electrical Check – Panel Box.
Electrical Check – Panel Box
Locate the breaker or fuses in your home’s main electrical panel for both the furnace and air conditioning unit. Make sure the breakers are not tripped or the fuses are not blown.
If your home has breakers, check to see if any are tripped. If a breaker has been tripped it will be in a position that is between ON and OFF. Reset the breaker (turn all the way OFF, then back ON).
If your home has fuses, check to see if the fuse for the furnace is blown. If so, replace it with the SAME SIZE AND TYPE of fuse. Do not increase the size of the fuse.
Warning: If a breaker keeps tripping or a fuse keeps blowing, you should contact a qualified service technician to inspect your system to determine why you are having problems.
Horizon Services Inc.
900 Adams Avenue
Audubon, PA 19403
(610) 444-6332
www.horizonservicesinc.com
Horizon Services Inc.
320 Century Blvd.
Wilmington, DE 19808
302-762-1200
www.horizonservicesinc.com