1. The circuit board voltage testThis test procedure is to test circuit boards master control chip of power supply voltage is normal or not. If working voltage normal, then jump next, otherwise display error information.
2, communication test
This test procedure is to test the PCM is normal or not, speaking, reading and writing and communication is normal or not, if test OK, then jump the next step.
3, initialization programming test
This procedure is mainly the EPROM code and constant write master control chip. If write successful automatic plunge into the next step. Don't succeed, display an error message.
4, temperature test
This test procedure is thermistor temperature, temperature range: 302.1 K + 40 K, if test OK, then jump the next step.
5 voltage precision test
This test procedure is to test the voltage PCM testing function are accurate. The testing principle is the PCM access a reference voltage, and then test machine through the SMBUS read BQ2060 internal register got voltage reference value. This project can judge PCM internal IC for each CELL voltage calculation are accurate, and can judge the PCM internal digital-to-analog conversion accuracy is normal or not. If the voltage error than 50 mv, the testing machine internal programmed decision for NG.
Six current precision test (0 current test)
This test is to PCM internal IC die/number adjusted (calibration), light as: 0000 ma, is not successful, display an error message.
7, charging test
The test is to test machine internal analog cell through the PCM battery charging for suppressing the simulation test, and if the test OK, then jump the next step.
8, discharge test the test is to test machine internal analog cell through the PCM simulation for suppressing the batteries discharge test, if test OK, then jump the next step.
9, slow filling test
This step is for more than 6000 mah hp Pavilion DV7 series Battery http://www.batterysale.net.au/hp/hp-Pavilion-DV7-series-battery.html and design. This test is judgment when the battery low voltage, cell whether can small current charging. If test OK, then jump the next step.
10 overcharge test
The test is to test the PCM overcharge test, overcharge point is: 4.38 V/CELL.
11 register backup test
This step is when the battery protection (overcharge or put), PCM internal RIGISTER data not loss. If the test through, then jump the next step.
12, name test
This step is to the battery information judgment test, if read information with the design information is consistent, have error message. If test OK, will put the cell battery core chemical name (LION), design capacity (2600 mah), model (CPI), time (2005-01-01) cycle times (0001) display.
The above is a test equipment forhp EliteBook 8540w Battery http://www.batterysale.net.au/hp/hp-EliteBook-8540w-battery.htmltest content, can see the laptop batteries need testing project about these items.