[Problem Description]Trigger condition:
There is a low possibility that the SSN1GSCC02 and SSN3GSCC02 boards manufactured earlier than August 9th, 2013 confronts this problem.
Symptom:
The SCC board occasionally reports the HARD_BAD (0xff 0xff 0xff 0×00 0×01) alarm that cannot be cleared after a warm reset due to an abnormal orderwire interruption. If the active SCC board is warm reset but does not report the HARD_BAD alarm, the NE is transiently unreachable for the NMS; if the active SCC board reports the HARD_BAD alarm, the active/standby switching is triggered. If the standby SCC board is warm reset, the standby SCC board reports the COMMUN _ FAIL (0×01 0×00 0×03 0xff 0xff) alarm, and the COMMUN-FAIL alarm clears after the standby SCC board starts working.
[Impact and Risk]
1. A traditional NE experiences a warm reset and no active/standby switching is triggered on a traditional NE housing two system control boards. If the active system control board or the single system control board of a traditional NE experiences a warm reset, the NE will become transiently unreachable by the NMS. If the standby system control board of the NE experiences a reset, there is no impact or risk.
2. During the active/standby switching, if data is being backed up in batches, data loss may occur.
3. If the active system control board of an ASON NE experiences a warm reset, the NE will lose the rerouting capability temporally so the services may interrupt.
Preventive measures:
Replace the problematic system control board with an SSN1GSCC02 or SSN3GSCC02 board manufactured in September 2013 or later, or with an SSN4GSCC board. For ASON NEs, replace the faulty SCC board with the SSN4GSCC board.